Closet Door 48 Inches

The Following Building Code Requirements Are The Current ...
Thick or longer than 48 inches. Exposed edges shall be smooth. Wired glass shall not be used in jalousies or louvered windows. 2. Hazardous Glass Locations. o. doors and closet door assemblies. 3. Storm Doors. 4. Unframed swinging doors. 5. ... Get Doc

Americans With Disabilities Act (ADA)
inches (100 mm). An alternate door location is illustrated to be on the side of the toilet stall with a maximum stile width of 4 inches required to be a minimum of 48 inches (1220 mm) in width. closet is 18 inches (455 mm) from a side wall. Title: Microsoft Word - GP_ADA_Info.DOC ... Access Doc

TECHNICAL CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES CHAPTER ...
Water closet. The door shall be self-closing. A door pull complying with 404.2.7 shall be placed Figure 604.8.1.1. to 48 inches (1220 mm) maximum above the shower floor and shall be located on the control wall 15 inches (380 mm) ... Document Viewer

The Closet Creature
Scratching his closet door. “Do you hear that?” Adam asked. David nodded. door a few more inches. A small furry creature ran right into the pillowcase. “I got it!” 6/28/2011 12:44:48 PM ... Visit Document

Home Assessment
Cabinet shelves are no more than 10 inches deep. Closet organizer to reach belongings. Ramp to front door with handrails on both sides. Microwave oven is no higher than 48 inches above the floor. Oven doors swing to the side. ... Retrieve Content

Stanley Architectural Hardware Catalog - Sliding & Folding ...
Inches mm inches mm inches mm Door Thickness 13/8" 35 13/4" 44 2" 51 lbs/ft 2kg/m lbs/ft kg/m2 lbs/ft2 kg/m2 Hollow Core 2 9.8 2 4 Door 48” opening BFC50-00-48 10 sets 25 lbs 40 2294 001 4 Door 60” opening BFC50-00-60 10 sets 28 lbs 40 2295 001 ... View Full Source

Www.adachecklist.org
Is there at least 24 inches of maneuvering clearance beyond the door latch side and at least 48 inches to the privacy wall if there is no door closer or at least 54 inches if there is a 3.48 If the water closet is wall hung, is the compartment at least 56 inches deep? Yes No. ... Fetch Document

CLOS-COOL Sellsheet.qxp 9/11/2006 4:04 PM Page 1
CLOSET COOLERremoves heat from All dimensions in inches unless otherwise noted [All dimensions in brackets are in millimeters] 15.71 [399] mounting holes.48 [12] 5.75 [146] 4.06 [103] 15.71 [399] SIDE VIEW REAR VIEW 1.30 [33] fits door widths from 1-3/8 to 1-3/4 ... Access Document

26-84132/1/0, 26-94132/1/0
2 Hot and cold inlet hose length on washer approximately 48.5 inches. 3 Drain hose length on washer approximately 59 inches. 4 d length on washer appr 53 1/2"* to clear open door 27" electrical Closet Door Installation in a recess or closet 1. ... Retrieve Here

Www.rider.edu
(wall to wall) 138 inches (11.5 feet) Length (door to window, excluding radiator) 168 inches (14 feet) Height (floor to ceiling, except (when standard university closet is intact) Width 48 inches (4 feet) Depth 27.5 inches (2 feet 3.5 inches) Room Dimensions. Greek Life Operations Manual ... Get Document

CHAPTER 6: PLUMBING ELEMENTS AND FACILITIES
From the centerline of the water closet 12 inches (305 mm) minimum on one side and 24 inches (610 mm) the compartment and any obstruction shall be 42 inches (1065 mm) minimum. The door shall be self- no higher than 48 inches (1220 mm) above the shower floor. ... Get Doc

APPENDIX B Design Quality Standards And Requirements
Pantry cabinet or closet door must be 24 inches minimum width. 4. All residential units must have either a dry chemical fire extinguisher mounted and readily visible be a minimum 48 inches long, and have a 30 by 48 inch clear floor space around it. ... Fetch Content

,d
And no higher than 48 inches (I 22 cm) from bottom washer. Support: Floor must be sturdy enough to support masher weight of 260 pounds (118 kihf$‘dlllS). Level floor: Maximum slope under entire washer - 3/8 inch (1 cm) Do Not store or ... Document Viewer

APPENDIX P R-2 OCCUPANCY TOILET AND BATHING FACILITIES ...
The door and frames are provided with mortised hinge and latch blanks to The centerline of the water closet shall be 16 inches (406 mm) minimum and 18 inches (457 mm) and 48 inches (1219 mm) minimum, measured ... View This Document

Americans With Disabilities Office
Reach shall be 48 inches (1220 mm) maximum and the low side reach shall be 15 inches is provided at a door, the sign shall be alongside the door at the latch side. ANSI closet 60 inches (1525 mm) minimum, measured perpendicular from the sidewall, ... Retrieve Full Source

Closet And Home Entertainment
Multi Media Rail with 48 moveable dividers Screw-mounted, accepts dividers for organizing CD’s, Inches are approximate Closet Accessories Tube and Hanger • The door is opened under spring tension by approx. 27º by simply applying ... View Doc

Tornado!
Earth's most powerful storms pack winds too furious to measure. Learn when and where they form and how we detect and survive them. ... Read News

2011 LABC Code Changes
48 inches deep maneuvering space shall be48 inches deep maneuvering space shall be provided in front of the water closet. The door shall be located in front of the clear floor space and diagonal to the water closet, with a maximum stile width of 4 inches. ... Return Document